Product name : CLIA Immunoassay Analyzer
Throughput : 280T/H
Platform : AP(Alkaline Phosphatase)
Aspirating method : Tips
Sample position : 96
Reagent position : 26
Reaction position : 145
Calibration : 2/6 points
Reagent : Over 70 kinds of test
280T/H Floor-standing Immunoassay Analyzer 15min for First Result Fully Automated Used in Hospital CLIA
Features:
1. Advanced detection principle
The magnetic particle separation chemiluminescence method adopts the current two mainstream immunoassay cutting-edge technologies in the world-magnetic particle carrier technology and chemiluminescence detection technology, which broadens the linear range of detection, improves detection sensitivity and analysis speed, and enables the system to fully meet clinical needs. Requirements for test results.
2. Strong detection throughput
Detection speed: 280T/H.
One-step and two-step on-machine testing at the same time.
The first result can be detected in as fast as 15 minutes, realizing the fastest detection.
3. Stable detection system
Reliable traceability system, traceability to international level professional data processing, intelligent management of calibration quality control with various calibration curve fitting methods, independent judgment of effectiveness.
4. Unique FITC/anti-FITC bridge technology
The superparamagnetic particles are used as the solid phase of the reaction, so that the reaction is more and sufficient, and it is easy to separate the alkaline phosphatase as the labeled enzyme. Compared with HRP, the background value is lower and the sensitivity is higher. It has advanced small molecule labeling technology to enhance the detection accuracy of small molecules.
5. Innovative AP-APLS chemiluminescence technology
High detection sensitivity, wide linear range, single-component substrate, strong stability, easy to use
Novel APLS luminescent substrate. The reaction plateau is reached quickly within 20s, the signal is continuously stable, easy to detect, avoid direct labeling of luminescent substances, not interfered by oxidants, and the signal is more stable.
Model | Automated Immunoassay Analyzer CIA2800 | |
Overall Performance | Throughput | 280 Tests/hour |
Repeatability | CV≤8% | |
Sample & Reagent System | Sample Positions | 96 sample positions |
Reagent Position | 26 reagent positions | |
Probe Washing | Automatic washing interior and exterior | |
Reagent Cooling | Refrigerated tray with independent switch | |
Reaction System | Temperature Control | 37+0.1℃, real-time monitoring |
Position | 145 | |
Mixer Probe | Independent stirring | |
Calibration | Calibration | 2/6-point |
Data Management | Software | Touch screen, English operation interface |
Thyroid | TSH |
TT3 | |
TT4 | |
FT3 | |
FT4 | |
TGAb | |
TPOAb | |
TRAb | |
TG | |
Fertility | FSH |
PRL | |
LH | |
E2 | |
TESTO | |
PROG | |
HCG | |
P/H-hcg | |
AMH | |
Glycometabolism & Hypophyseal Hormone | C-P |
INS | |
Hepatic Fibrosis | PIIINP |
HA | |
LN | |
CIV | |
Tumor Markers | CEA |
AFP | |
CA125 | |
CA19-9 | |
CA15-3 | |
CA50 | |
CA72-4 | |
CA242 | |
T-PSA | |
F-PSA | |
TK1 | |
FERRITIN | |
SCC | |
NSE | |
CYFRA21-1 | |
HE4 | |
S100 | |
Hp-Ab | |
TPS | |
TNF-α | |
GP73 | |
PIVKAⅡ | |
PACP | |
Inflammation Monitoring | IL-6 |
PCT | |
CRP | |
CAA | |
Cardiac | cTn |
MYO | |
CK-MB | |
HFABP | |
NT-pro-BNP | |
D-Dimer | |
HCY | |
BNP | |
Lp-pla2 | |
ST2 | |
TORCH | |
Infectious | HBsAg |
HBsAb | |
HBeAg | |
HBeAb | |
HBcAb | |
Anti-HCV | |
Anti-HIV | |
Anti-TP | |
NP-IgG | |
NP-IgM | |
Kidney Function | NGAL |
H-ALB | |
RBP | |
Cys-C | |
β2-MG | |
Gastric Mucosa Function | PGⅠ/Ⅱ |
PRO-GRP | |
GRP-17 |
![]() |
280T/H Floor Standing Immunoassay Analyzer CLIA 15min For First Result Fully Automated Used In Hospital CLIA Images |